UMG 512-PRO - 52.17.011

img
 

UMG 512-PRO - 52.17.011. Trojfázový analyzátor sítě s jmenovitým napětím až 347/600 V AC. Napájecí napětí 95-240 V AC, 80-300 V DC. Paměť Flash, kapacita 256 MB. Rozhraní RS 485, Profibus DP, Ethernet, software GridVis.

Cena s DPH 154 154 Kč
Cena bez DPH 127 400 Kč
Běžná cena 155 727 Kč
Ušetříte 1%
Dostupnost sdělíme na dotaz
množství 
 
 
Kategorie: UMG 512
Kód: UMG 512-PRO - 52.17.011
Záruka:
Výrobce: Janitza electronic GmbH
 
 

Areas of application

• Continuous monitoring of the power quality
• Harmonics analysis with power quality problems
• Checking the internal supply network according to EN 61000-4-7, EN 6100-4-15, EN 61000-4-30
• Fault analysis in case of problems with the energy supply
• Documentation of the power quality for customers and regulatory authorities
• Ethernet Gateway for subordinate measurement points
• Report generator for power quality standards: EN 50160, IEE519, EN61000-2-4, ITIC …
• Report generator for energy consumptions
• Energy Dashboard
• Remote monitoring of critical processes

Main features

Power quality

• Harmonics analysis up to the 63rd harmonic, even / odd (U, I, P, Q)
• Interharmonics (U, I)
• Distortion factor THD-U / THD-I / TDD
• Measurement of positive, negative and zero sequence component
• Unbalance
• Direction of rotation feld
• Voltage crest factor
• Flicker measurement in accordance with DIN EN 61000-4-15
• Logging and storage of transients (> 39 µs)
• Short-term interruptions (> 10 ms)
• Monitoring start-up processes

High quality measurement

• Constant true RMS measurement
• Measurement process in accordance with IEC 61000-4-30
• Certifed accuracy of measurement according to class A
• Continuous sampling of the voltage and current measurement inputs at 25,6 kHz
• 512 measurement points per period
• Recording of over 2,000 measured values per measurement cycle
• Accuracy of active energy measurement: Class 0.2S
• Fast measurement even enables the logging of rapid transients from 39 µs
• Logging of currents and voltages (15 – 440 Hz)

RCM (Residual Current Monitoring)

• Continuous monitoring of residual currents (Residual Current Monitor, RCM)
• Alarming in case a preset threshold fault current reached
• Near-realtime reactions for triggering countermeasures
• Permanent RCM measurement for systems in permanent operation without the opportunity to switch off
• Ideal for the central earthing point in TN-S systems

User-friendly, colour graphical display with intuitive user guidance

• High resolution colour graphical display 320 x 240, 256 colours, 6 buttons
• User-friendly, self-explanatory and intuitive operation
• Backlight for optimum reading, even in darker environments
• Illustration of measured values in numeric form, as a bar graph or line graph
• Clear and informative representation of online graphs and power quality events
• Multilingual: German, English, Russian, Spanish, Chinese, French, Turkish ...

Various characteristics

• 4 voltage and 6 current measurement inputs
• 2 digital inputs, e.g. as data logger for S0 meter
• 2 digital outputs for alarm message or e.g. for connection to a BMS or PLC
• Free name assignment for the digital IOs, e.g. if used as data logger

Comprehensive communication and connection possibilities

• Modbus
• Profbus
• Ethernet (TCP/IP)
• Digital IOs
• BACnet (optional)
• Confgurable Firewall

Modern communications architecture via Ethernet

• Simple integration in an Ethernet network
• Reliable and cost-optimised establishment of communication
• Ideal for Master-Slave structures
• High flexibility due to the use of open standards
• Integration in PLC systems and BMS through additional interfaces
• Various IP protocols: SNMP, ICMP (Ping), NTP, FTP …
• Up o 4 ports simultaneous

Measuring device homepage

• Web server on the measuring device, i.e. device's inbuilt homepage
• Function expansion possible through APPs
• Remote operation of the device display via the homepage
• Comprehensive measurement data incl. PQ (transients, events…)
• Online data directly available via the homepage, historic data optional via the APP measured value monitor, 51.00.245 BACnet protocol for building communication
• Optimal interoperability between devices from various manufacturers
• Predefned BIBBs (BACnet Interoperability Building Block)
• BACnet is optionally available with UMG 512
• UMG 512 supports the device type B-SA with the BIBBs DS-RP-B and DS-WP-B
• Furthermore, the BIBBs DS-COV-B and DM-UTC-B are also supported

Modbus Gateway function

• Economical connection of subordinate measuring devices without Ethernet interface
• Integration of devices with Modbus-RTU interface possible (harmonisation of data format and function code necessary)
• Data can be scaled and described
• Minimised number of IP addresses required
• Tried and tested integrated solution without additional hardware

Programming / PLC functionality

• Further processing of the measurement data in the measuring device (local intelligence)
• Monitoring and alarm functions simple to program
• Sustainable functional expansions far beyond pure measurement
• Comprehensive programming options with
- Jasic® source code programming
- Graphical programming
• Complete APPs from the Janitza library

Large measurement data memory

• 256 MB data memory
• Memory range up to 2 years (confguration-dependent)
• Individually confgurable recordings
• Recording averaging times can be freely selected
• PQ recordings template preconfgured for conventional standards (e.g. EN 50160)
• User-defned memory segmenting possible

Powerful alarm management

• Information available immediately by email
• Inform maintenance personnel via the powerful device homepage
• Via digital outputs, Modbus addresses, GridVis® software
• Programming via Jasic® or graphical programming
• Further alarm management functions via GridVis®-Service alarm management

Peak load representation and peak load management

• Illustration of the 3 highest monthly power peaks on the LCD display (P, Q, S)
• Rolling bar chart representation of the peak power values over 3 years on the LCD display (P, Q, S)
• Plain text representation on the LCD display (P)

GridVis®-Basic power quality analysis software

• Multilingual
• Manual read-out of the measuring devices
• Manual report generation (power quality and energy consumption reports)
• Comprehensive PQ analysis with individual graphs
- Online graphs
- Historic graphs
- Graph sets
• Integrated databases (Janitza DB, Derby DB)
• Graphical programming
• Topology views
• High memory range

Certifed quality through independent institutes

• ISO 9001
• Energy management certifed according to ISO 50001
• Class A certifcate (IEC 61000-4-30)
• UL certifcate
• EMC-tested product

 

 
 

Nastavení cookies

Abyste na našich stránkách rychle našli to, co hledáte, ušetřili spoustu klikání a nezobrazovaly se vám reklamy na věci, které vás nezajímají, potřebujeme od Vás souhlas se zpracováním souborů cookies, tj. malých souborů, které se ukládají ve vašem prohlížeči. Podle cookies vás na našich stránkách poznáme a zobrazíme vám je tak, aby všechno fungovalo správně a dle vašich preferencí. Souhlas udělíte kliknutím na políčko „OK“.

Nastavení